Calomax Quantum Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Aquecedores e fervedores de água Calomax Quantum. quantum full manual issue 3.indd Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 9
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Quantum
Read these instructions thoroughly
before commencing installation or
undertaking maintenance work.
Issue 3 - DCR 674:8/6/05
TEL: 0113 249 6681 FAX: 0113 235 0358 www.calomax.co.uk
Counter-top Catering Water Boiler
INSTALLATION, OPERATION AND
MAINTENANCE MANUAL
Vista de página 0
1 2 3 4 5 6 7 8 9

Resumo do Conteúdo

Página 1 - MAINTENANCE MANUAL

QuantumRead these instructions thoroughly before commencing installation or undertaking maintenance work.Issue 3 - DCR 674:8/6/05 TEL: 0113 2

Página 2 - CONTENTS

CONTENTS3. INSTALLATION . . . . . . . . . 34. COMMISSIONING . . . . . . . . . 35. USER INSTRUCTIONS . . . . . . . . 3 5.1 Cleaning . . . . . . . . .

Página 3

PAGE 1NB15BLGbody lidgasketTAK thermistorassembly kitNBE3HKelement(Wrapper not shown for clarity)CASMR manualreset thermostatCASLPK kitcomprising 3 of

Página 4 - 2. PLANNING THE INSTALLATION

2. PLANNING THE INSTALLATIONAll installation and maintenance work must be carried out by competent persons.2.1 Water RequirementsThe unit is designed

Página 5 - 3. INSTALLATION

4. COMMISSIONING1. Turn water supply on2. Turn electrical supply onOn initial switch-on onlyAfter a few seconds delay for the electronics to charge

Página 6 - 6. MAINTENANCE

Fig. 5 5.1 CleaningWhen required the unit should be wiped down with a damp cleaning clothThe unit is not protected against the ingress of water and th

Página 7

Before re-commissioning the unit, all scale and moisture must be removed from the level sensor insulating gaskets to avoid false signalling through th

Página 8

ISSUE 3 PAGE 67. FAULT FINDINGTo protect the unit in the event of continuous over boiling, the unit is fi tted with a thermal cut-out device. This devi

Página 9 - CONNECTOR PLUG

ISSUE 3 PAGE 7Wiring Schematic for Calomax Quantum Water Boiler using v10 boardREDYELLOWBLACKBLUEPINKBROWNORANGEWHITE+12Vdc (BROWN)BLACKRED0.75mm YELL